Argox PA-60 User Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 41
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
l: Maximum column count.
18
C Counter
t: Truncation flag, 0=normal and 1=truncated.
o: Rotation. 0-0
o
, 1-90
o
, 2-180
o
and 3-270
o
.
Syntax Cp
1
,p
2
,p
3
,p
4
,”MSG”
Note: The specifications of PDF-417 and Maxi Code are
Description This command defines a counter variable. It is useful in
released by AIM International, Inc..
printing the labels numbered in sequence. In general, it will be used
together with the Form function.
Example N
b10,10,P,400,300,s0,x3,y7,r10,l2,t0,
To print the contents of the counter, you may use A (print
"ARGOXINFO"
text) or B (print bar code) commands.
A10,150,0,3,1,1,N,"ARGOXINFO"
P1
Parameters p
1
: Counter ID. Acceptable value ranges from 00 to 99.
p
2
: Maximum digit number. Acceptable values are from 1 to
Output
29.
p
3
: Justification code. L for left justification, R for right
justification, N for no justification and C for centralization.
p
4
: Amount to increment or decrement the field by. There
should be a + or - sign before the step value.
“MSG”: A text string that will be sent to KDU or host.
Example N
FK"TEST"
FS"TEST"
C0,6,N,+1,"Enter Code:"
A100,100,0,4,1,1,N,"Label: "
A300,100,0,4,1,1,N,C0
FE