b Prints 2D Bar Code
Syntax bp
1
,p
2
,p
3
,[specific parameters and data]
Description Prints a specific 2D bar code.
Parameters p
1
: X coordinate in dots. p
2
: Y coordinate in dots.
p
3
: 2D bar code type.
p
3
Value Bar Code
P PDF-417
M Maxi Code
Note:
The sub-string of counter and variable can be applied to the B command.
Syntax Vn[st,len]
Cn[st,len]
Maxi Code [“CL,CC,PC,Data”]
Where : n is the counter or variable ID.
CL: Class code, 3 digits.
st is the start location (the first location is 0),
CC: Country code. 3 digits.
len is the length of the sub-string.
PC: Post code, 4 or 5 digits for USA and 6 characters for
other countries.
Example C00[1,2] ; A sub-string of counter 0, starting from 1 and length is 2.
Data: Up to 84 characters.
PDF-417 [w,v,s,c,p,x,y,r,l,t,o],”Data”
w: Maximum print width in dots.
v: Maximum print height in dots.
s: Error correction level, 0 ~ 8.
c: Data compression level, 0 or 1. The default value is 0.
x: Module width, 2 ~ 9 in dots.
y: Module height, 4 ~ 99 in dots.
r: Maximum row count.
15
16
Page view 7