Argox AS Series Quick Start User Manual

Browse online or download User Manual for Scanners Argox AS Series Quick Start. Argox AS Series Quick Start User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 33
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
NOTICE:
This equipment has been tested and complied with
the limits for a Class a digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to
provide a reasonable protection against harmful
interface when the equipment is operated under a
commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful interface to
radio communications. Operation of this equipment in
a residential area is likely to cause harmful interface in
which case the user will be required to correct the
interface at his own expenses.
Note: All brands and trademarks shall belong to their
respective owner.
Note: Specification is subject to changes without
notice.
This device complies with Part 15 of the FCC Rules.
Operation shall be subject to the following two
conditions:
(1) This device may not cause harmful interface, and
(2)
This device must accept any interface received,
including interface that may cause undesirable
operation.
Page view 0
1 2 3 4 5 6 ... 32 33

Summary of Contents

Page 1 - NOTICE:

NOTICE: This equipment has been tested and complied with the limits for a Class a digital device, pursuant to Part 15 of the FCC Rules. These limits

Page 2 - Using the ArgoxScan

7 Keyboard Wedge Combo Connector (To Host Side): Pin Mini-DIN 6P Male DIN 5P Female 1 DATA / PC DATA / KB 2 NC NC 3 GND GND 4 VCC (

Page 3 - Introduction

8 Keyboard Wedge PS/2 Connector (To Host Side): Pin Mini-DIN 6P Male Mini-DIN 6P Female 1 DATA / PC DATA / KB 2 NC NC 3 GND GND 4 VCC (+5V)

Page 4 - Programming the ArgoScan

9 Scan Mode Good-read off Momentary * Alternate Timeout off Continue Test only Stand Mode Enable Stand mode +

Page 5

10 Suffix Characters Setting (Keyboard Wedge & USB) Enter * Tab None

Page 6 - Keyboard Layout - Continued

11 Enable Barcode Industrial 2 of 5 Matrix 2 of 5 Eur Standard 2 of 5 Codabar Code 93 Code 11 MSI/Plessey UK/Plessey Telepen China Post I

Page 7

12 Enable Barcode - Continued EAN UCC Composite (for 8312) RSS-14 RSS-Limited RSS-Expanded Micro-PDF (for 8312) Note: All oth

Page 8

13 UPCA Supplement digits (for 8120/8150/8250) None * 2 digits 5 digits UCC/EAN 128 Auto detection

Page 9 - Pin Assignments

14 UPCA Supplement digits (for 8310/8312) None * 2 digits 5 digits 2, 5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All

Page 10

15 UPCE Supplement digits (for 8120/8150/8250) None * 2 digits 5 digits UCC/EAN 128 Auto detection

Page 11

16 UPCE Supplement digits (for 8310/8312) None * 2 digits 5 digits 2, 5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All

Page 12

Using the ArgoxScan 8000/8120/8150/8250/8310/8312 The ArgoxScan can automatically scan barcode at a distance. Simply aim and pull the trigger. Code sc

Page 13 - (Keyboard Wedge & USB)

17 UPCA Truncation/Expansion None * Truncate leading zero Expand to EAN-13 UPCE Truncation/Expansion None * Truncate leading zero Ex

Page 14 - Enable Barcode

18 EAN-13 Supplement digits (for 8120/8150/8250) None * 2 digits 5 digits UCC/EAN 128 Auto detection

Page 15 - Enable Barcode - Continued

19 EAN-13 Supplement digits (for 8310/8312) None * 2 digits 5 digits 2, 5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All

Page 16 - (for 8120/8150/8250)

20 EAN-8 Supplement digits (for 8120/8150/8250) None * 2 digits 5 digits UCC/EAN 128 Auto detection

Page 17 - (for 8310/8312)

21 EAN-8 Supplement digits (for 8310/8312) None * 2 digits 5 digits 2, 5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All

Page 18 - UPCE Supplement digits

22 ISBN/ISSN Conversion Disable * Enable EAN-8 Expansion None * Truncate leading zero

Page 19

23 Code 39 Check-sum setting Verification Disable * Verification Enable Transmit Disable * Transmit Enable Code 39 Format setting S

Page 20

24         CODABAR-PARA (8110 *)

Page 21 - EAN-13 Supplement digits

25 PDF-417 (8250/8312 *) STANDRAD-25 PARA CODE-16K EAN-8 PARA * INDUSTRIAL-25 PARA UPCE PARA * 

Page 22

26 INTERLEAVED-25 PARA * MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA * UK/PLESSEY PARA GS1 Databar Micro-PDF (8312 *)

Page 23 - EAN-8 Supplement digits

0 Introduction Installation- Keyboard Wedge 1) First of all, you must switch off power for the terminal/computer. 2) Disconnect the keyboard cable

Page 24

27 ASCII Code Table ﹛﹜

Page 25

28 Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your AS-8110/

Page 26

29 Exit Query present scanner firmware version Program Firmware version list If yo

Page 27

30 0 1 2 3 4 5 6 7 8 9 A B C Finish F E D

Page 28

1 Programming the ArgoScan 8110/8120/8150/8250/8310/8312 To program the 8110/8120/8150/8250/8310/8312, you must scan a series of programming barcode

Page 29

2 Interface Selection Keyboard Wedge RS-233 Wand Emulation (8110/8150/8250) USB Keyboard /RS232/USB * Auto detection

Page 30 - ASCII Code Table

3 Keyboard Layout - Continued France Germany Italian Portuguese Spanish Swedish Switzerland UK Latin American Japanese

Page 31

4 RS-232 Flow Control None * RTS/CTS Xon/Xoff ACK/NAK RS-232 Baud Rate Setting 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600

Page 32

5 RS-232 Baud Rate Setting (Continued) 19200 BPS 38400 BPS RS-232 Parity Setting None * Odd Even RS-232 Data Bit Setting 8 b

Page 33

6 Pin Assignments AS Series 8-pin RJ-45 Connector Pin RS-232 Keyboard 1 VCC (+5V) VCC (+5V) 2 TXD NC 3 NC CLK / PC 4 NA DATA / P

Comments to this Manuals

No comments