PT-Basic Programming Manual Ver. 1.00 68/143
DISPFONT_INFO_WIDTH
Purpose
To get font width.
Syntax
A%=DISPFONT_INFO_WIDTH(FontID %)
Example
B%=DISPFONT_INFO_WIDTH(3)
Description
A% is an integer variable to be assigned to the result.
FontID% is an integer variable in the range from 2 to 9.